Get chiller related information TCU Air Cooled Chillers Recirculating Chiller Dynamic Temperature Control Systems 产品分类菜单

CHILLERS

Temperature Range -115℃~100℃;Temperature Accuracy ±0.1℃

Air cooling type & Water cooling type

Applications: semiconductor |aerospace | automotive | new energy | chemical | industry production

We Have got your apps covered.no replacement.

LNEYA® can design & make all types of chiller meet your demands.Process chiller capacity 0.5 Ton to 500 Ton; Process chiller capacity 0.5 Ton to 500 Ton; High-efficiency scroll/screw type compressor;Cooling industrial process or manufacturing; Remote operation to monitor and regulate process temperatures.For more details, please consult with LNEYA engineers.

Recirculating Chillers

Temperature accuracy ±0.5℃

Refrigeration Chillers

Semiconductor Chillers

Automotive Chillers

Can be used for cooling the heating part of the semiconductor manufacturing device, cooling the heating part of the laser device, and cooling the heating part of the analysis and detection machine, cooling the heating part of laboratory reactors.

Model LT 10℃~30℃  LT-25℃~30℃ LT -45℃~30℃ LT -60℃~-30℃ LT -80℃~-40℃
Cooling Capacity 3KW~14KW 1.5KW~5KW 1.6KW~4.8KW 0.7KW~4.8KW 0.4KW~2.5KW
Flow Control 30L/min~50L/min
Refrigerant R-134A / R407C R-404A / R507C R-404A / R507C R-404A/R23 R-404A/R23
Temp control accuracy ±0.5℃ ±0.5℃ ±0.5℃ ±0.5℃ ±0.5℃
Cooling capacity 3KW~14KW@15℃ 1.5kw~5kw@-15℃ 0.7kw~2.5kw@-35℃ 1.3kw~4.8kw@-40℃ 0.7kw~2.5kw@-60℃

Widely used in high-tech industries such as petrochemical, medical, pharmaceutical, biochemical, freeze-drying, pharmaceutical and so on such as Injection water system, extraction machine, etc.

Temp Range LTZ -40℃~90℃  LTZ 5℃~30℃ LTZ -25℃~30℃ LTZ -45℃~20℃ LTZ -60℃~-30℃ LTZ -80℃~-50℃ LTZ -115℃~-80℃
Cooling Capacity 0.7KW~11.5KW 23KW~300KW 7KW~117.5KW 2.85KW~61.56KW 4.9KW~93.2KW 3.7KW~78.5KW 0.6KW~2.8KW
Heating Power 2.5kW~10KW            
Temp control accuracy ±0.3℃ ±0.3℃ ±0.3℃ ±0.3℃ ±0.3℃ ±0.3℃ ±0.3℃
Temperature feedback Temperature feedback PT100 (inlet temperature, outlet temperature)
Compressor Highly, Mitsubishi, Panasonic and other compressors
Evaporator Plate Heat Exchanger
Operation panel 4.3-inch color touch screen displays set temp and measured temp, records temp curve, and exports data in Excel format
Safety protection Self-diagnosis function; refrigerator overload protection; high and low pressure sensors, overload relays, thermal
protection devices and other safety protection functions
Power AC220V / AC380V/ AC460V
Shell material Cold rolled sheet (REL7035)
Communication protocol Communication protocol MODBUS RTU protocol RS485 interface

Cooling photolithography, dry etching; Cooling the furnace body and walls; Cooling CVD reaction chambers and equipment; Cooling targets and PVD equipment; Cooling ion implantation equipment; Cool the grinding disc and equipment, Cooling packaging equipment and mold

Model FLTZ Single Channel Series Multi-channel Series Heat Exchange Series ETCU
Temp Range -45℃~+90℃ -45℃~+100℃ 5℃~+90℃
Cooling Capacity 1KW~40KW 2KW~6KW 5KW~300W
Temperature control accuracy ±0.05℃ ±0.05℃ ±0.05℃
Cooling water flow @20℃ 1.5m³/h~9m³/h 1.2m³/H~10.2m³/H 1.5m³/H~8m³/H

FLTZ series 5℃~90℃  -25℃~90℃  -45℃~90℃  -80℃~+90℃  -100℃~+90℃
Temperature control accuracy ±0.05℃ ±0.05℃ ±0.05℃ ±0.05℃ ±0.05℃
Cooling capacity 6KW~40KW @10℃ 2KW~15KW @-15℃ 1KW~8KW @-35℃ 0.6KW~3KW @-70℃ 1.5KW~3KW @-90℃
Cooling water flow @20℃ 1.5m³/h~9m³/h 1.2m³/H~10.2m³/H 1.5m³/H~8m³/H 1.8m3/h~6m3/h 50L/min~100L/min
Temperature feedback Temperature feedback PT100 (inlet temperature, outlet temperature)
Compressor Highly, Mitsubishi, Panasonic and other compressors
Evaporator Plate Heat Exchanger
Operation panel 4.3-inch color touch screen displays set temp and measured temp, records temp curve, and exports data in Excel format
Safety protection Self-diagnosis function; refrigerator overload protection; high and low pressure sensors, overload relays, thermal
protection devices and other safety protection functions
Power AC220V / AC380V/ AC460V
Shell material Cold rolled sheet (REL7035)
Communication protocol Communication protocol MODBUS RTU protocol RS485 interface

Temperature simulation for vehicle quality test: battery life test, fuel injector/motor test bench, airbag test, component test bench, etc. It can simulate the external environmental conditions in the climate chamber or replace the internal system, which can create the necessary actual temperature conditions for the test bench.

Model KRY -20℃~+100℃ KRY -40℃~+100℃ KRY -20℃~+100℃ 6S KRY -40℃~+100℃ 6S KRY -40℃~+100℃ 2T KRY 0℃~+100℃ KRY 0℃~+100℃ 6S KRY -40℃~+100℃ 2T
Temp control accuracy ±0.3℃
Flow rate accuracy ±0.2 L/min
Heating capacity 5.5KW~38KW 5.5KW~60KW 15KW~38KW 15KW~38KW 7.5KW*2~38KW*2 2.5KW~38KW 15KW~38KW 2.5KW*2~38KW*2
Cooling capacity 2.8KW~38KW 1.2KW~60KW 10KW~60KW 5KW~60KW 1.8KW*2~60KW*2 1.8KW~60KW 18KW~60KW 1.8KW*2~60KW*2
Power 380V50HZ 11KW~45KW 10KW~84KW 36KW~75KW 38KW~82KW 28KW~158KW 4.5KW~61KW 38KW~82KW 9KW~120KW
Temperature feedback Temperature feedback PT100 (inlet temperature, outlet temperature)
Compressor Highly, Mitsubishi, Panasonic and other compressors
Evaporator Plate Heat Exchanger
Operation panel 4.3-inch color touch screen displays set temp and measured temp, records temp curve, and exports data in Excel format
Safety protection Self-diagnosis function; refrigerator overload protection; high and low pressure sensors, overload relays, thermal
protection devices and other safety protection functions
Power AC220V / AC380V/ AC460V
Shell material Cold rolled sheet (REL7035)
Communication protocol Communication protocol MODBUS RTU protocol RS485 interface

We offer a wide range of chiller models, tailored to your application. If you have any questions about any of the parameters, please contact us.

WhatsApp +86 18914253067

WeChat 18914253067

Industry-Leading Technologies

Chiller Temperature Range 
LNEYA industrial chillers are built for demanding low-temperature applications, performing best below -60℃. They cover a wide range from -150℃to 350℃to fit your specific needs.

High-precision Chiller  
LNEYA industrial chiller systems use three-point temperature sampling (inlet,outlet, and target), combined with a model-free algorithm and hysteresis prediction. This ensures precise temperature control with ±0.02℃ accuracy and stable, repeatable performance

Rapid cooling chiller system 
LNEYA industrial chillers use advanced inverter technology to precisely control compressor speed. With smart electronic expansion valve adjustment, they achieve rapid cooling and support long, continuous operation.

Energy-efficient chiller
LNEYA industrial chiller units use an inverter compressor, pump, and fan to adjust speed based on real-time load. This reduces power consumption, keeps the system running smoothly, and helps lower your operating costs.

Applications

Installation Photos

Customized Chillers for Your Process Needs

We use a variety of internationally renowned accessories, all of which can be customized for your needs, such as compressors, evaporators, heat exchangers, circulation pumps, controllers, expansion valves and shell materials, etc.

CUSTOM CHILLER SIZES

Whether it is portable, compact, large and small chillers, we can custom design them according to your requirements.
No matter how many tons of chiller you need, we can create the best solution.

CUSTOM TEMPERATURE RANGES

We can create a custom solution for temperatures from -150℃ to +350℃.
Custom temperature ranges for specific industries.

CUSTOM CHILLER TYPES

We provide chillers of various refrigeration types, including but not limited to air-cooled, water-cooled and evaporative-condensing chillers.
Regardless of the type of refrigeration compressor, we can design it according to your requirements.

CUSTOM COOLING CAPACITY

We offer a very wide range of cooling capacities for various industries.

Your Trusted Source for Chillers Manufacturer

LNEYA’s industrial chiller/heater is sold globally. Singapore, Malaysia, Japan, South Korea, Qatar, Middle Eastern countries, Australia,various European countries such as Netherlands, Spain and United States and other regions.

CONTACT US

*
*
Submitting!
Submitted successfully!
Submission failed!
Email error!
Phone error!